Our Quality Assurance Standards

Quality assurance at DiFruscia Industries rests on three things: a registered quality management system, control of every process, and a laboratory of our own that proves the result. DiFruscia Industries is an EPA permitted and established facility, staffed with experienced coaters who are committed to excellence and precision.

Certifications and accreditation

ISO 9001:2015 and AS9100:2016 (AS9100D), registered by NQA, USA. Certificate no. 19918; certified since April 1, 2021; valid until March 31, 2027. Scope: Type II anodizing and Type III hard coat, PTFE, ceramic coating, powder coating, dry film lube, chem film, electroplating of brass, copper, electroless nickel, nickel, tin and zinc, passivation and phosphate, for medical, aerospace, military and commercial applications. View certificate (PDF)

Nadcap accreditation for Chemical Processing (AC7108), administered by the Performance Review Institute (PRI). Certificate no. 21888247430; expires November 30, 2027. Listed on the Qualified Manufacturers List at eAuditNet.com. It covers anodizing Type II and Type III (bright dip included), chem film, passivation, the MIL-PRF-23377 primer, the MIL-PRF-85285 topcoat and in-house testing. Every other process is performed under our AS9100D quality system and is not a Nadcap special process. View certificate (PDF)

ITAR registration. DiFruscia Industries is registered with the U.S. Department of State under the International Traffic in Arms Regulations (ITAR). CAGE code: 7MD08.

Cerakote Certified Applicator. The certificate is on our Cerakote page.

All current certificates, and how to request quality documents: Certifications & Approvals. About the aerospace standard: AS9100 Certified.

Quality control is process control

We don’t inspect quality into a part at the end of the line. We control the process that produces the finish, and then we test to prove it.

  • Documented procedures. All of our systems, recipes and procedures are documented and reviewed under our quality manual.
  • Quality planning. We plan quality into the job with control plans, PFMEA and PPAP.
  • Validation. Processes and equipment are validated to written protocols.
  • A recipe for every part. Our production management software stores the recipe for each part through every step of its process. It also shows where your job is in the system and lets us predict deliveries accurately.
  • Daily analysis. Every process solution is on a scheduled daily analysis and titration, which keeps each bath within its operating window.
  • SPC chemistry control. Chemistry monitoring software tracks every bath and charts its trend (statistical process control), so adjustments are made before parts are affected.
  • ICP analysis. Our Agilent 5800 ICP-OES measures metals and contaminants in our process solutions.
  • Tested and documented. Finished parts are tested in-house, and the results are documented for your quality records. A Certificate of Conformance and packing list come with each order.

Controlled chemistry means consistent results from the first lot to the hundredth. In-house testing means faster answers when you need data for a first article or a qualification.

In-house laboratory and testing

Our laboratory’s equipment, and what each piece does for your parts:

  • X-Rite color spectrophotometer. Measures color as numbers (CIE L*a*b*) against a standard, so a color match is measured and documented, not judged by eye.
  • SPC chemistry control software. Tracks the analysis of every bath and charts its trend.
  • Agilent 5800 ICP-OES. Measures metals and contaminants in process solutions.
  • Hach DR3900 spectrophotometer. Colorimetric analysis of water and solution samples.
  • Titration. Volumetric and wet titration techniques for the daily analysis of every process solution.
  • Taber abraser. Measures the wear resistance of hard coat and other coatings under a standardized abrasion wheel.
  • Salt spray chambers. Test the corrosion resistance of coated panels and parts in controlled salt fog (ASTM B117).
  • Memmert HCP105 humidity chamber and environmental oven. Conditions metal test panels and parts before testing.
  • Adhesion testing. Shows how well a coating bonds to the part, by tape test for example.
  • Bowman XRF analyzer. Measures plating thickness on finished parts by X-ray fluorescence, a non-destructive check against your drawing and specification.
  • DeFelsko PosiTector 6000 eddy current gauge. Measures coating thickness on aluminum and other non-ferrous metals, also without damaging the part.
  • Coating weight testing. Measures coating weight where a specification calls for it.

Color difference plot from DFI's spectrophotometer: measured parts inside the tolerance ellipse

A color-difference plot from DFI’s spectrophotometer. Each point is a part measured against the color standard; the ellipse is the tolerance.

DFI’s Laboratory and Testing data sheet (TDS-QA-01) is available on request from Technical Specifications. To price a job, request a quote.